dell 2950 error E2022 post fail

June 27, 2013 at 09:24:15
Specs: Windows 7
I have a dell poweredge 2950 running window server 2003 used as Technical monitoring and configuration system for our vcs. The server halted. I restarted the server, it couldnot boot
the system unit screen shows E2022 Post fail. The monitor shows PCLe Training error: Embeded I/o bridge device 6. Any help on how to go about it is highly welcomed.
George

See More: dell 2950 error E2022 post fail

Report •

#1
June 27, 2013 at 09:32:11
Have you read this article?
It may help solving the problem.

http://en.community.dell.com/suppor...


Report •

#2
June 27, 2013 at 10:36:54
Thanks Paulsep, I have read it, it does not seem to help me. But what does embedded I/o bridge device 6 indicate

Report •

#3
June 27, 2013 at 12:19:52
Try to reseat thr empty riser cards of the server.

Report •

Related Solutions

#4
June 28, 2013 at 01:14:41
Thanks paulsep, please how i do start dell 2950 in safe mode

Report •

#5
June 28, 2013 at 10:17:03
As you do on e.g. Windows 2000/XP, Windows Vista or Windows 7.
Press the F8 key right after the BIOS screen.
You might have to press it more than once.

Report •

#6
July 3, 2013 at 06:45:38
Hi, Paulsep,
Thanks for ur help. I latter noticed that two capacitors, 1500uF/6.3V on the PCIe daughter card were swollen at the top. I replaced them with 1000uF/16V as I could not find the exact value. The server came on and boot ok. I installed the server into the rack and everything worked ok. The server stopped working again after about 3 days showing E2119 and E1410 fatal errors with regard to processor and CRC memory. I reseat the ram chips and the processor fans. I also reconnect the ground connection between the server and the rack which I had earlier removed in the course of taking out the server from the rack. The server has been working ok for the past 24 hrs. I hope it continue to do so. Thanks.

Report •

#7
July 3, 2013 at 08:47:30
Good luck for that ...!!!

Report •