Computing.Net > Forums > Disk Operating System > printing to EPSON TM-U950 in com1/2

Computer Problems? Computing.Net has over 1,000,000 posts about all things technology related! Over 90% answered within 24 hours! Click here to start participating now! Also, be sure to check out the New User Guide.

printing to EPSON TM-U950 in com1/2

Reply to Message Icon

Name: huncho
Date: June 29, 2002 at 03:01:01 Pacific
Comment:

hi. i have been trying to print to my epson tm-u950 POS printer which i connected to com2 (and com1 just to check if it will work there) and failed to print everytime. these are what i did (all in msdos622 command prompt):

1. mode com2: baud=9600 data=8 parity=n stop=1
2. mode lpt1:=com2:
3. tried to print by:
a. typing 'dir *.* >prn'
b. or, running foxpro 2.5 and then printing from there.

i can sense that the printer is connected because if i turn it off, DOS will display an error message. if it's on, there's no such message. however, nothing's printed.

h-e-l-p.



Sponsored Link
Ads by Google

Response Number 1
Name: cup
Date: June 29, 2002 at 13:49:00 Pacific
Reply:

1) Have you tried 2 stop bits? The start and stop bits is just timing: nothing is actually transmitted. You can have 1, 1.5 or 2 stop bits. Epson recommends 1 but 2 works too.

2) Are there any switches on the printer that set the baud rate?

3) I'm not familiar with this printer - is there a test mode which will print the internal settings? On my FX850, it is switch the printer off, hold down the FF button, switch on the printer and then wait for it to print before releasing the FF button.

4) You may need to loopback 4&5 and 6&20. These are hardware control signals for DSR, DTR, CTS and RTS (not respectively). It is possible that your PC is waiting for a CTS before it transmits and the printer is not raising the signal. Check your mode command. Does it have an odsr option? Try playing with odsr, octs, dtr, idsr and rts if it does. Your printer may magically come to life.


0

Response Number 2
Name: huncho
Date: July 7, 2002 at 06:15:05 Pacific
Reply:

thanks cup.

1. i tried 2 stop bits. didn't work. :(

2. there's this pair of dip switches at the bottom of the printer. i didn't bother to change the baud rate (maybe i should). i matched the current setting with what's in the manual and set the MODE parameters accordingly. nothing still worked.

3. the funny thing about this is that if i try to do the same things (i did in dos which didn't work) in windows 98, it would work ONLY WHEN i print a test page first.

4. i tried the test page trick. it prints 100% of the time.

5. maybe i should try your last suggestion which at the moment is still too cryptic to me. well, just the same, thank you very much.



0

Sponsored Link
Ads by Google
Reply to Message Icon

Related Posts

See More


++++++++Partitions+++++++ DR-DOS does not mount FAT...



Post Locked

This post is quite old and has been locked from receiving new replies. Please create a new posting instead.


Go to Disk Operating System Forum Home


Sponsored links

Ads by Google


Results for: printing to EPSON TM-U950 in com1/2

Printing Autocad 12 for dos in Windows 95 www.computing.net/answers/dos/printing-autocad-12-for-dos-in-windows-95/5849.html

Printing to a serial printer from DOS www.computing.net/answers/dos/printing-to-a-serial-printer-from-dos/6150.html

COm1 Port config. to print in DOS www.computing.net/answers/dos/com1-port-config-to-print-in-dos/16139.html